1~12KW Inverse Control One Machine
    发布时间: 2024-04-13 15:11    

1~12KW Inverse Control One Machine

1~12KW Inverse Control One Machine
DNK series
Model1k1.5k2k3k5k6k7k
Rated power1kW1.5kW2kW3kW5kW6kW7kW
BatteryBattery voltage12VDC/24VDC    24VDC/48VDC48VDC48VDC
Over
discharge
protection
voltage
10.5VDC/21VDC       
(Default)
21VDC/42VDC
(Default)
42VDC
(Default)
42VDC
Battery typeLead acid or lithium battery
Mains
power
input
PhaseSingle phase+G
Input voltageAC220V/230V±15%
Frequency50Hz/60Hz±5%
Mains charging
current
15A(Max),30A(Max)
MPPT
controller
Input the number of
photovoltaic panels
1
Input voltage
range
DC16~180V
/DC36~180V
DC36~180V
/DC60~180V
DC60~180V
Recommended
operating voltage
45Vdc80Vdc110Vdc
Maximum open
circuit voltage
180Vdc
Rated current40A60A/80A60A/80A80A
Equalizing charging
voltage
14.2V/12V;28.4V/24V;56.8V/48V
Constant charging
voltage
14V/12V;28V/24V;56V/48V
Float charging
voltage
13.5V/12V;27V/24V;54V/48V
Efficiency≥96.5%
Inverter
output
AC output voltage220Vac/230Vac:±5%
Output frequency50Hz/60Hz:±1%
Output waveformPure sine wave
Inverter efficiency>90%
Overload capacity101%~120%/30s;>125%300ms;
Protection
function
Battery overvoltage protection,battery undervoltage protection,
overload protection, short circuitprotection, over temperature
protection,etc
Switching time10ms
Isolation modePower frequency transformer
Overall
performance
Operating temperature0~40℃
Storage temperature-40~+70℃
Relative humidity0~90%(non condensing)
Size(mm)480*335*160580*385*195740*450*225
Package size(mm)535*350*210645*400*240792*460*252
Net weight(KG)1316.51926.25/31384345.8
Gross weight(KG)14.3172227.2/31.538.544.546.2
Electrical specifications(8kW/10kW/12kW)
Model8kW10kW12kW
Inverter
output
Continuous output power80001000012000
Surge rated power(20ms)24kW30kW36kW
Output waveformPure sine wave/same as input(bypass mode)
Overall efficiency88%(Peak value)
Line mode efficiency0.95
Effective value of
rated output voltage
100~110~120Vac/220~230~240Vac
Output voltage regulation± 5% effective value
Output frequency50Hz+0.3Hz/60Hz+0.3Hz
Short circuit protection1s after fault
Conversion time10ms
Power factor0.9~1.0
DC
input
Rated voltage48.0Vdc
Minimum starting voltage46Vdc
Low voltage warning43Vdc±1Vdc
Shut down when the
battery is low
42Vdc
High voltage warning59Vdc alarm, 60Vdc protection
Low battery voltage
recovery
>44Vdc
No load consumption<150W when power saving
is turned on
ChargeOutput voltageDepends on battery type
Maximum charging powerOne third of rated power
Overvoltage protection60Vdc
BatteryBattery temperature
sensor
Charging voltage and step-down
voltage change with temperature
Bypass
protection
Input voltage protectionSine wave
Rated voltage220/230/240Vac
Maximum input
AC voltage
150Vac is used for 220Vac low-voltage mode;
300Vac for 230Vac high voltage mode
Input frequency50Hz/60Hz
Overload protectionCircuit breaker
Output short-circuit
protection
Circuit breaker
Bypass without battery
connection
Optional
Mechanical
parameters
Installation modeWall mounted/horizontal
Inverter size(mm)800*460*250
Package size(mm)865*510*300
Net weight(KG)56.559.561.5
Gross weight(KG)63.56668.5
DisplayLED/LED-LCD